€ 53,71
Descriere
With this micomodule Z-Wave, you can control motors shutters, blinds, garage doors, gates, venetian blinds etc.. This box from your home automation, but also through a local switch connected to the module.
This module is also environmentally friendly: its own energy consumption is less than 0.4 W and continuously measures the instantaneous energy used (in Watts) and total consumption (kWh) of furnace pilot . Consumer devices can thus be retrieved from a box automation-compatible, allowing you then to be vigilant in relation to your energy expenditure.
But this is not all, since this module also has an input for connecting a temperature sensor, making it very efficient to manage a system of heating, ventilation or air conditioning for example.
Finally, it is noted that the QUBINO brand has set bond quality and durability they have so carefully chosen performance components such as relay OMRON. Many quality control tests were also performed on the module to ensure maximum durability (strong enough to operate in temperatures ranging from -10 ° C to 40 ° C).
Its implementation is very simple, thanks to a small size, and the ability to use any type of supply (AC or DC).
FUNCTIONS:
- Order your blinds or shutters remote
- Moved behind an existing switch
- Up / down and positioning
- The smallest unit for roller shutter world
- Case design specially designed for ease of installation (easy fixing cables), tested by professional electricians
- Very low power consumption less than 0.4W
- Operating temperature -10 to 40 ° C
- Connector for analog temperature sensor
- Measurement of power consumption
SPECIFICATIONS:
- Power supply: 110-230 VAC ± 10% 50/60Hz, 24-30VDC
- Power Consumption: 0.4 W
- AC nominal output current (resistive load): 2 X 4A / 230VAC
- Nominal DC output current (resistive load): 2 X 4A / 30VDC
- Power output AC circuit (resistive load): 2 X 920W (230VAC)
- Power circuit DC output (resistive load): 2 X 96W (24VDC)
- Accuracy of measurement of energy: P = 0-200W + /-2W; P> 200W + / -3%
- Transmitting radio frequency: 868.42MHz, Z-Wave
- Range: up to 30 m indoors (depending on surrounding materials)
- Measuring range of digital temperature sensor (sensor sold separately): -50 ~ 125 ° C
- Operating Temperature: -10 ~ 40 ° C
- Space required for installation: Ø ≥ 60mm
- Dimensions (W x H x D): 41.8 x 36.8 x 16.9 mm
- Weight: 25g
- Certifications: CE, RoHs
Specificaţii
Primary Controller Compatibility | |
---|---|
1 eeDomus+ | full compatible |
Fibaro Home Center 2 v4.160 | partial |
Fibaro Home Center Lite v v.4.160 | partial |
Zipabox/Zipaminicro/ZipaTile | full compatible |
Piper / Piper NV (v.1.7.1) | full compatible |
Indigo | no tested |
jeedom | |
Domoticz | no tested |
ZiHome | full compatible |
49 Vera 3 | full compatible |
49 Vera Lite | full compatible |
Tech Data | |
50 IP Rating | |
51 Power Supply | 110 - 230 VAC ±10% 50/60Hz, 24-30VDC |
53 Explorer Frames - NWI Support | |
54 SDK | |
56 Device Type | Slave |
57 Peper1 Database link | |
58 Z-Wave Alliance Product Link | |
95 Generic Device Class | Multilevel Switch |
96 Specific Device Class | motorized blinds controller |
97 Routing | |
Procedures | |
90 Incluison | Connect module to power supply (with temperature sensor connected - if purchased). Press service button S for more than 2 second or press push button I1 three times within 3 seconds. For auto-inclusion, first set main controller into inclusion mode an then connect the module to power supply (the auto-inclusion works for about 5 seconds after that) |
91 Exclusion | Connect the module to power supply, enable add/remove mode on main controller and press the service button S for more than 6 seconds or press push button I1 five times within 3 seconds in the first 60 seconds after the module is connected to the power supply. (If the service button S is pressed more than 2 and less than 6 secons it will be excluded but not resetted) |
92 Factory Reset | Connect the module to power supply, enable add/remove mode on main controller and press the service button S for more than 6 seconds or press push button I1 five times within 3 seconds in the first 60 seconds after the module is connected to the power supply. (If the service button S is pressed more than 2 and less than 6 secons it will be excluded but not resetted) |